|
Search:     Advanced search
Browse by category:
Glossary | Contact Us



ZBuilder Quality of Fit

Add comment
Views: 679
Votes: 0
Comments: 0
Posted: 23 May, 2012
by: Collura T.
Updated: 13 May, 2013
by: Milicia R.

The following graphs show a sample fit of data from 1 minute of EEG .  Note that we compute statistics on every sample at 256 samples/second so that one minute of data produces over 15,000 data points for each parameter.  The first graph is a typical fit of amplitude data to a normal distribution.  It is a typical, and not a particularly great example, to be fair.  The second graph is one that is somewhat better, also typical  The table at the end of this article is a summary of quality of fit for 3 transformations of the data, showing that the "fourth root" gives the best fit.  Each number is the correlation between the data distribution and the best Gaussian fit.  Considering all channels and all components, the best fit is better than 0.99, and the worst fit is better than 0.94.  This proves that even 1 minute of EEG data can provide sufficiently high quality statistics to be used for live z-score training.

 

 

 

Others in this Category
document Live Z-Score Training with the ANI Z DLL
document Doerte Klein Z Score Training Planning Sheet
document Towards a Coherent View of Brain Connectivity - Journal of Neurotherapy Final PDF Online
document How well do live Z Scores match the NeuroGuide Z Scores?
document What is the most important thing about live Z Score training?
document Z Score White Paper
document Will z score training replace the clinician?
document Z score training combined with amplitude training - how it works
document Z-scores and Golf
document Mark Smith's Z Score Basic Training Workshop--Protocol Designs
document Z Score All to Target Except Absolute Power - Separate Upper and Lower limits
document Multivariate Proportional (MVP) Targeting - what is it and how is BrainMaster different?
document Case Studies on z-score training compiled
document Live Z-Scores - how to review?
document Joseph Guan Z-Score Training Data Sheet
document Live Z-Score with Ultra Low Frequency 2 or 4 channel
document Installer for new CVIRT drivers for ANI Z DLL
document Z-PLUS LZT Live Z-Score Training Software Revised with Z-Bars and Z-Maps Display
document Live Z-Score Training - Typical Single-Session Changes
document Amplitude or Power Training - Case Study
document Z-Score Setup Settings File
document Z-PLUS Documentation and Design by Neils Schnepel
document New York University EEG Live Z-Score Database
document New York University EEG Database References
document Static versus Dynamic Z-Scores
document BrainAvatar comparison with surface maps
document Sufi self-piercing with live sLORETA Z-Score image
document Comparison of BrainDX and ANI surface maps



RSS