|
Search:     Advanced search
Browse by category:
Glossary | Contact Us



Discovery 24E Mindset Simultaneous Map Comparisons

Add comment
Views: 1027
Votes: 0
Comments: 0
Posted: 10 Dec, 2009
by: Collura T.
Updated: 02 Dec, 2011
by: Collura T.

The following maps were made from data taken simultaneously on a Mindset 24 and a Discovery 24.  In order to get them to match, it was necessary to reduce the frequency response of the Discovery 24, by turning on both the 60 Hz and the 50 Hz filters.  The Mindset has a high frequency cutoff of 34 Hz, while the Discovery has a high frequency cutoff of 52 Hz.  If the goal is to make them match, then the Discovery should have both the 60 Hz and the 50 Hz filters turned on.

With the exception of the higher response of the Discovery in Beta and High Beta, the maps are identical.  It is our opinion that the Discovery map is the more accurate, since the frequency response of the Discovery is more even across the entire passband, and NeuroGuide is better able to see the beta activity in Discovery.

 

The second set was done with the filters redesigned to better match the Mindset 1.5 - 34 Hz response.  The raw EEG as well as the maps are identical, except for slightly more delta (about 50% more) detected with the Discovery amplifiers, which is expected.  The attached pdf file provides details of raw waveforms and maps of all metrics including coherence , phase , and asymmetry .

 

 

Attached files
file Disc-Mindset_Compare_screens_12-15-09.pdf (3.53 mb)

Also read
document Discovery 24E comparison tests

Others in this Category
document MINI-Q II with Live Z-scores protocol design
document Discovery 24E Channel EEG / DC amplifier
document Discovery 24E EEG NeuroGuide Screen
document Discovery 24E EEG Loreta Low-Resolution EEG Tomography
document Discovery 24E NeuroGuide maps
document Discovery 24E specs
document Discovery 24E Sensor and Offset Information
document Discovery Training Information
document Discovery 24E comparison tests
document Discovery 24E Evoked Potentials
document Discovery 24E with WinEEG
document Discovery Evoked Potentials using EEGLab
document Installation and Use for 19-channel Live Z-Score Training using Discovery
document Live Z-Score Training - Typical Single-Session Changes
document 10-10 system chart
document Discovery 1.5.6 ILF Software 0.001 Hz Response
document Ensuring high-quality EEG recordings
document Discovery Firmware Field Upgrade Process
document I just did the Discovery Firmware Upgrade, and now I cannot log into NeuroGuide. What Do I Do?
document Z-FOCUS enhanced Z-Plus design by Hai Pham Dinh
document Z-Score Insomnia Study - Barbara Hammer
document BrainAvatar Questions and Answers
document BrainAvatar sLORETA Regions of Interest (ROI's)
document Neils Schnepel BrainAvatar Live Loreta Training Results
document BrainAvatar Settings Files Set 1
document AMHCA San Francisco Talk - Neurofeedback in Mental Health
document EMG Protocols



RSS