The attached paper shows an implementation of the protocol described in the following paper:

Egner, T. and Sterman, M.B. Neurofeedback treatment of epilepsy: from basic rationale to practical application. Expert Rev. Neurotheraputics 6(2) 247-257 (2006).

This protocol uses the Event Wizard to perform the following:
Inhibit theta (4-8 Hz) on channel 1 (T4 or F8)
Enhance low beta (SMR = 12-15 Hz) on channel 2 (C4)
Provide single tone feedback immediately when conditions are met
Provide a refractory period of 2 seconds after each reward
Manual adjustment of thresholds.
Attached files
file Sterman_Egner_Protocol_Design_080227121814.bmz (14 kb)
file Implementation_of_Sterman_protocol.pdf (77 kb)

Others in this Category
document Z Score protocol five coherences normal UL
document Can I do alpha/theta training with BrainMaster?
document Simple method to downtrain hypercoherence
document Four Channel Alpha Synchrony Protocol
document Gamma SCC (Spectral Correlation Coefficient) Uptraining Settings File Example
document Downtrain SMR and Beta Design
document Flash Games 2-15-08 Distribution
document Coherence uptraining with beta inhibit
document coherence downtraining
document Z Scores PercentZOK with alpha uptraining
document Decrease Percent Energy Alpha
document Z score training combined with amplitude training - how it works
document Research - Placebo controlled double-blind studies with EEG Biofeedback - Methods
document Z-Score PercentZOKUL with 4-channel alpha enhance - Mark Smith
document Somatic Vision Games with Advanced Protocols
document How to Convert a Downloaded Protocol Design into a Settings File
document Research - Choice of 4-channel montage for quick assessment
document Z Score PercentZOKUL with Four Channel Inhibit__Mark Smith
document Z score questions regarding different bands in the DLL versus BrainMaster, and coherence training
document Protocols for HemiSync training - 2 and 4 channels
document Variability Downtraining Question
document Excess SMR downtraining via. z-scores - comments
document Downtraining variability of variability
document Z Scores with Peak2 C3 Beta C4 SMR
document Z Theta Down Protocol Design
document Two-Hz Bins with 8 bins and training via. Event Wizard, all games working



RSS